Q-Switched Nd:YAG
1064 nm
- Best suited for
- Carbon facials · Black · Blue · Dark green tattoo pigments
- Diffusion d’énergie
- 1064 nm · 0.4–0.8 J · 10 ns
- Operating speed
- Selectable 1 / 2 / 3 Hz
Tattoo Removal & Carbon Glow
A compact standalone workstation for two of today’s most in-demand services — precise laser tattoo removal and the coveted carbon facial glow — with intuitive controls and dual-wavelength Q-switched Nd:YAG performance.

Aperçu de la plateforme
Rapid QS is a dedicated Q-Switched Nd laser platform engineered for safe, precise, and effective tattoo removal and carbon facial treatments. Utilizing advanced Q-Switched technology, the system delivers ultra-short 10 ns, high-energy pulses across a documented 0.4–0.8 J range, selectively targeting tattoo pigment while minimizing thermal impact on surrounding tissue. Selectable 1, 2, or 3 Hz repetition rates and spot sizes of 2 mm, 4 mm, or 6 mm provide practitioners with enhanced control and treatment flexibility. Intelligent treatment parameters, developed from SharpLight’s extensive clinical expertise and proven patient outcomes, support consistent treatment protocols.
The dual-wavelength system enables practitioners to switch between 1064 nm and 532 nm wavelengths using the integrated KTP adaptor, allowing treatment to be tailored to different tattoo ink colours. The 1064 nm wavelength targets darker pigments such as black and blue, while 532 nm is ideal for brighter pigments including red and yellow. The platform also supports carbon facial treatments for improved skin clarity, refined texture, and gentle exfoliation. Its compact footprint makes it an ideal, high-revenue addition to any aesthetic practice.
532 + 1064 nm
Wavelengths
10
ns pulse width
2 / 4 / 6 mm
Spot sizes
Conception de la plateforme
Turn every treatment room into a revenue generator with the Rapid QS—a compact Q-Switched laser for effective tattoo removal and carbon facial treatments.
Quickly switch between 1064 nm and 532 nm using the integrated KTP adaptor.
The interface brings wavelength, spot size, repetition rate, pulse energy, session count, and system status into one treatment process.
A 102.7 × 44 × 46 cm workstation is designed for controlled movement between professional treatment rooms.

Choose from 2 mm, 4 mm, and 6 mm spot sizes to accurately treat everything from fine details to larger areas.
Protects the laser system for reliable performance throughout every treatment.
Laser is activated only when both the foot switch and handpiece trigger are engaged, enhancing operator control and treatment safety.
Meet the handpiece
One QS LASER handpiece supports 1064 nm delivery and a 532 nm KTP configuration, with three spot sizes shared across both wavelengths.
Q-Switched Nd:YAG
Q-Switched Nd:YAG
Why choose Rapid QS
One dedicated Q-switched platform. Four practical advantages across professional tattoo-removal protocols.
Move between 1064 nm and 532 nm KTP configurations as tattoo colour and documented test response require.
Choose from 2 mm, 4 mm, and 6 mm spot sizes to precisely treat everything from fine details to larger areas.
Deliver 10 ns Q-switched pulses through a controlled 0.4–0.8 J operating range and selectable 1–3 Hz repetition.
Bring test treatment, wavelength choice, spot-size selection, energy settings, and safety controls into one focused platform.
On the treatment floor
Q-switched Nd:YAG laser in a compact workstation — handpiece docked and ready for tattoo removal and carbon facial protocols.
Référence technique

Documented outcomes
Explore documented before-and-after imagery relevant to Rapid QS. Drag the divider across each image to inspect the result from either side.
Individual results vary by patient, protocol, practitioner, and treatment plan.


Réponses aux questions cliniques
Des renseignements pratiques pour les cliniques qui évaluent la plateforme.
L’admissibilité au traitement, les paramètres et les soins après traitement doivent être déterminés par un praticien SharpLight formé, à la suite d’une consultation et d’un test cutané.
Rapid QS is a professional Q-switched Nd:YAG laser workstation intended for adult tattoo-removal treatments in cosmetic clinics, medical clinics, and private clinics. It is operated by trained professionals qualified in aesthetic and dermatological applications.
A short, high-intensity laser pulse is selectively absorbed by tattoo pigment. Rapid pigment disruption occurs through a photo-acoustic mechanism, after which the released particles are cleared through the body’s natural processes.
Wavelength choice, response, and removal efficiency vary with ink composition, colour, depth, density, and the patient’s individual response.
The system uses one QS LASER handpiece with 2 mm, 4 mm, and 6 mm spot sizes. A KTP optical unit changes the operating wavelength from 1064 nm to 532 nm.
Rapid QS delivers a 10 ns pulse width, 0.4–0.8 J per pulse, and selectable repetition rates of 1, 2, or 3 Hz.
The manual requires test treatment before continuing so the practitioner can evaluate tissue response, potential allergic reaction, and possible tattoo darkening. The tested settings and response should be documented in the patient record.
Contactez notre équipe pour réserver une démo et constater les résultats par vous-même. Investissez dans votre entreprise avec une technologie d’esthétique médicale transformative.