Tattoo Removal & Carbon Glow

Q-Switched Nd:YAG. Tattoo & Carbon.

A compact standalone workstation for two of today’s most in-demand services — precise laser tattoo removal and the coveted carbon facial glow — with intuitive controls and dual-wavelength Q-switched Nd:YAG performance.

  • Small footprint
  • 1064 & 532 nm
  • Intuitive controls
Book a demo
Rapid QS

Aperçu de la plateforme

One Q-Switched Platform, with Two-Wavelength Flexibility

Rapid QS is a dedicated Q-Switched Nd laser platform engineered for safe, precise, and effective tattoo removal and carbon facial treatments. Utilizing advanced Q-Switched technology, the system delivers ultra-short 10 ns, high-energy pulses across a documented 0.4–0.8 J range, selectively targeting tattoo pigment while minimizing thermal impact on surrounding tissue. Selectable 1, 2, or 3 Hz repetition rates and spot sizes of 2 mm, 4 mm, or 6 mm provide practitioners with enhanced control and treatment flexibility. Intelligent treatment parameters, developed from SharpLight’s extensive clinical expertise and proven patient outcomes, support consistent treatment protocols.

The dual-wavelength system enables practitioners to switch between 1064 nm and 532 nm wavelengths using the integrated KTP adaptor, allowing treatment to be tailored to different tattoo ink colours. The 1064 nm wavelength targets darker pigments such as black and blue, while 532 nm is ideal for brighter pigments including red and yellow. The platform also supports carbon facial treatments for improved skin clarity, refined texture, and gentle exfoliation. Its compact footprint makes it an ideal, high-revenue addition to any aesthetic practice.

  • 532 + 1064 nm

    Wavelengths

  • 10

    ns pulse width

  • 2 / 4 / 6 mm

    Spot sizes

Conception de la plateforme

Compact design. Dedicated Q-switched platform

Turn every treatment room into a revenue generator with the Rapid QS—a compact Q-Switched laser for effective tattoo removal and carbon facial treatments.

  • Dual-wavelength versatility

    Quickly switch between 1064 nm and 532 nm using the integrated KTP adaptor.

  • 10.2-inch colour touchscreen

    The interface brings wavelength, spot size, repetition rate, pulse energy, session count, and system status into one treatment process.

  • Compact mobile footprint

    A 102.7 × 44 × 46 cm workstation is designed for controlled movement between professional treatment rooms.

Rapid QS Q-switched Nd:YAG workstation with mounted handpiece
Dedicated dual-wavelength Q-switched workstation
  • Precision Spot Size Selection

    Choose from 2 mm, 4 mm, and 6 mm spot sizes to accurately treat everything from fine details to larger areas.

  • Advanced cooling technology

    Protects the laser system for reliable performance throughout every treatment.

  • Dual-Action Safety Controls

    Laser is activated only when both the foot switch and handpiece trigger are engaged, enhancing operator control and treatment safety.

Meet the handpiece

One handpiece.
Dual wavelength.

One QS LASER handpiece supports 1064 nm delivery and a 532 nm KTP configuration, with three spot sizes shared across both wavelengths.

Dark Tattoos & Carbon

Q-Switched Nd:YAG

1064 nm

Best suited for
Carbon facials · Black · Blue · Dark green tattoo pigments
Diffusion d’énergie
1064 nm · 0.4–0.8 J · 10 ns
Operating speed
Selectable 1 / 2 / 3 Hz
Coloured Tattoos

Q-Switched Nd:YAG

532 nm KTP

Best suited for
Red · Orange · Yellow · Bright green tattoo pigments
Diffusion d’énergie
532 nm KTP · 0.4–0.8 J · 10 ns
Operating speed
Selectable 1 / 2 / 3 Hz
1QS LASER handpiece
2Wavelengths
3Spot sizes
I–VSkin types

Détail de la pièce à main

HR 635

01 / 02

Profil latéral

Why choose Rapid QS

Precision across the spectrum

One dedicated Q-switched platform. Four practical advantages across professional tattoo-removal protocols.

Wavelength choice

Wavelength-specific targeting

Move between 1064 nm and 532 nm KTP configurations as tattoo colour and documented test response require.

Treatment precision

Treatment Precision

Choose from 2 mm, 4 mm, and 6 mm spot sizes to precisely treat everything from fine details to larger areas.

Pulse delivery

Nanosecond pulse delivery

Deliver 10 ns Q-switched pulses through a controlled 0.4–0.8 J operating range and selectable 1–3 Hz repetition.

Clinical protocol

Structured practitioner protocol

Bring test treatment, wavelength choice, spot-size selection, energy settings, and safety controls into one focused platform.

En salle de traitement

Rapid QS workstation in a treatment room
01 / 02

Full workstation — mobile base with dual handpiece cradles

Référence technique

Rapid QS technical specifications

Rapid QS workstation in a front three-quarter studio view
Rapid SeriesRapid QS

Core technology & delivery

Platform technology
Q-switched Nd:YAG laser
Wavelengths
1064 nm · 532 nm with KTP optical unit
Pulse width
10 ns
Pulse energy
0.4–0.8 J per pulse
Repetition rate
1 / 2 / 3 Hz

System & hardware

Display
10.2-inch colour touchscreen
Electrical
120–240 V~, 50–60 Hz, 12 A max
Dimensions
102.7 cm H × 44 cm W × 46 cm D
Total weight
53 kg
Handpiece cooling
Water cooled with flow and temperature monitoring

Treatment interface

Handpiece
QS LASER
Spot sizes
2 mm · 4 mm · 6 mm
Wavelength adapter
Removable 532 nm KTP optical unit
Skin types
Fitzpatrick I–V
Emission controls
Foot switch + handpiece trigger

Documented outcomes

See the difference.
Control the view.

Explore documented before-and-after imagery relevant to Rapid QS. Drag the divider across each image to inspect the result from either side.

Individual results vary by patient, protocol, practitioner, and treatment plan.

Après — Tattoo Removal case 1
Avant — Tattoo Removal case 1
AvantAprès

Réponses aux questions cliniques

Rapid QS
questions fréquentes

Des renseignements pratiques pour les cliniques qui évaluent la plateforme.

L’admissibilité au traitement, les paramètres et les soins après traitement doivent être déterminés par un praticien SharpLight formé, à la suite d’une consultation et d’un test cutané.

What is the SharpLight Rapid QS?

Rapid QS is a professional Q-switched Nd:YAG laser workstation intended for adult tattoo-removal treatments in cosmetic clinics, medical clinics, and private clinics. It is operated by trained professionals qualified in aesthetic and dermatological applications.

How does Q-switched tattoo removal work?

A short, high-intensity laser pulse is selectively absorbed by tattoo pigment. Rapid pigment disruption occurs through a photo-acoustic mechanism, after which the released particles are cleared through the body’s natural processes.

What is the difference between the 1064 nm and 532 nm configurations?
  • 1064 nm is used for Carbon Facial treatments and dark tattoos including black, blue, and dark green.
  • The 532 nm KTP configuration is used for coloured tattoos including red, orange, yellow, and bright green when clinically appropriate.

Wavelength choice, response, and removal efficiency vary with ink composition, colour, depth, density, and the patient’s individual response.

Which handpiece and spot sizes are supplied?

The system uses one QS LASER handpiece with 2 mm, 4 mm, and 6 mm spot sizes. A KTP optical unit changes the operating wavelength from 1064 nm to 532 nm.

What is the operating range?

Rapid QS delivers a 10 ns pulse width, 0.4–0.8 J per pulse, and selectable repetition rates of 1, 2, or 3 Hz.

How often are Rapid QS treatments performed?
  • Tattoo Removal: 1 treatment every 8 weeks, typically 6–8 treatments.
  • Carbon Facial: up to 1 treatment every 3–4 weeks, or every 1–2 weeks for acne reduction.
Why is a test spot important?

The manual requires test treatment before continuing so the practitioner can evaluate tissue response, potential allergic reaction, and possible tattoo darkening. The tested settings and response should be documented in the patient record.

Réservez votre démo aujourd’hui!

découvrez sharplight en action

Contactez notre équipe pour réserver une démo et constater les résultats par vous-même. Investissez dans votre entreprise avec une technologie d’esthétique médicale transformative.

  • Plateformes multi-technologies et mono-technologies
  • Plus de 60 indications cliniques, 16 pièces à main
  • Essai pratique des séries OmniMax et Rapid
Demander une démo
Brochure du produit

Télécharger la brochure Rapid QS

Indiquez-nous comment vous joindre et la brochure s’ouvrira immédiatement.