DPC™ hair-reduction interface
HR 635
- Indications
- Body hair reduction · Face hair reduction · Pseudofolliculitis barbae
- Diffusion d’énergie
- DPC™ · 635 nm family
- Operating speed
- Protocol-dependent pulse delivery
OmniMax flagship / Four technologies
Four technologies.One flagship platform.
A flagship multi-technology workstation bringing DPC™, radiofrequency, VermaDerm™ infrared, and laser into one configurable platform for a broad professional treatment menu.
On the treatment floor
See the OmniMax S4 flagship workstation, modular handpiece protocol, and four-technology treatment platform in motion.
Product videoVoir la vidéoAperçu de la plateforme
OmniMax S4 consolidates four professional aesthetic technologies into one flagship workstation: Dynamic Pulse Control™ intense pulsed light, radiofrequency, VermaDerm™ long-pulsed infrared, and laser.
The DPC™ family addresses application-specific light protocols with dedicated optics for hair reduction, inflammatory acne, rejuvenation, and selected vascular and pigmented lesions. CoolTip™ sapphire contact cooling at the DPC™ interface supports epidermal protection and comfort.
Radiofrequency and VermaDerm™ infrared add face-and-body thermal protocols, while Fractional Er:YAG 2940, long-pulsed Nd:YAG 1064, and Q-switched Nd:YAG 1064/532 handpieces extend the platform into resurfacing, deeper vascular, tattoo-removal, and carbon-facial applications.
Twelve interchangeable handpieces, protocol-based default parameters, manual control for trained users, and organized workstation storage bring the treatment menu into one familiar operating environment.
4
Core technologies
12
Application-specific handpieces
60+
Clinical indications
Conception de la plateforme
Six protocol details connect technology selection, protocol control, mobility, CoolTip™ sapphire cooling, handpiece organization, and broad treatment capability in one flagship platform.
DPC™, radiofrequency, VermaDerm™ infrared, and laser modalities share one configurable clinical workstation.
Default parameters based on SharpLight clinical protocols support a structured starting point with manual control for trained users.
A wheeled platform keeps broad treatment capability organized within a practical professional treatment-room footprint.

Purpose-built configurations support multiple energy-based technologies within a single platform.
Built-in CoolTip™ sapphire cooling on DPC™ and VermaDerm™ handpieces supports epidermal protection and patient comfort.
Accessible holders keep the selected applicators secure and ready as the practitioner moves between treatment categories.
Meet the handpieces
Application-specific DPC™, radiofrequency, infrared, and laser handpieces move across the flagship treatment menu without changing platforms.
DPC™ hair-reduction interface
Facial radiofrequency interface
Focused infrared interface
Fractional Er:YAG resurfacing
Why choose OmniMax S4
One flagship workstation. Four practical advantages across a broader professional treatment menu.
Bring hair, skin, contouring, vascular, pigment, resurfacing, and tattoo-removal protocols into one configurable platform.
Match the selected indication to a dedicated DPC™, radiofrequency, infrared, or laser handpiece and its documented treatment geometry.
Use the four technology families independently or build practitioner-led treatment plans that sequence complementary modalities. Integrate advanced stacked treatment methodologies for superior results.
Centralize parameter selection, protocol access, handpiece organization, and system status in one clinic-ready workstation.
On the treatment floor
A flagship workstation that keeps modular treatment capability, clinical controls, and a compact mobile footprint together in one room-ready platform.
Proprietary technology
Select a technology to see how it delivers energy, what makes it distinct, and where it fits into the OmniMax S4 treatment menu.
Technology 01
One IPL platform shapes pulse delivery around the target, skin type, and clinical indication.
SharpLight’s configurable intense pulsed light platform. Application-specific handpieces filter the broad spectrum for hair, acne, vascular, and pigmentation protocols.
Smooth, Long, and High pulse structures alter how energy is distributed over time. This lets the practitioner match heating behavior to target depth and the selected treatment protocol.
Clinical value
Technology 02
Electrical resistance converts bi-polar face and multi-polar body RF energy into controlled heat within dermal and subcutaneous tissue.
A non-invasive thermal modality for facial and body treatments, delivered through bi-polar face and balanced six-pole multi-polar body electrode configurations.
Energy passes between electrodes and is converted into heat by tissue resistance. Real-time impedance measurement helps calibrate delivery as tissue conditions change during treatment.
Clinical value
Technology 03
Long infrared pulses target water in deeper dermal tissue to produce sustained, controlled thermal stress.
A long-pulsed infrared modality designed for deep tissue heating, with water acting as the principal absorber in the skin.
Infrared energy penetrates into the reticular dermis. Multi-second pulses heat water-rich tissue, supporting immediate collagen contraction and the longer-term remodeling response.
Clinical value
Technology 04
Focused wavelengths create highly specific optical interactions for resurfacing, vascular, tattoo, and hair protocols.
A family of monochromatic laser modalities, each selected for a distinct chromophore, penetration depth, and tissue response.
Erbium YAG gently creates microchannels; Long-pulse Nd:YAG delivers laser energy to deeper tissue targets; Q-switched Nd:YAG delivers nanosecond photo-acoustic energy.
Clinical value
Référence technique

Real results. Real patients.
Explore SharpLight before-and-after results. Drag the divider to inspect each result.
Individual results vary by patient, protocol, practitioner, and treatment plan.


“Unlike other competitor technologies, SharpLight’s platform offers faster results with fewer treatments using their proprietary DPC technology. Combining this elite technology with both superior customer service and marketing support makes SharpLight easily stand out from other med-aesthetic companies.”
Réponses aux questions cliniques
Des renseignements pratiques pour les cliniques qui évaluent la plateforme.
L’admissibilité au traitement, les paramètres et les soins après traitement doivent être déterminés par un praticien SharpLight formé, à la suite d’une consultation et d’un test cutané.
OmniMax S4 is SharpLight’s flagship multi-technology aesthetic workstation. It brings DPC™ intense pulsed light, radiofrequency, VermaDerm™ long-pulsed infrared, and three laser modalities into one configurable professional platform.
The OmniMax S4 configuration supports 12 application-specific handpieces across its DPC™, radiofrequency, infrared, and laser families. The installed configuration can be matched to the clinic’s approved treatment menu.
Depending on the installed handpieces, practitioner training, and local clearances, the platform can support protocols for hair reduction, inflammatory acne, skin rejuvenation and tightening, facial and body contouring, selected vascular and pigmented lesions, fractional resurfacing, tattoo removal, and carbon-facial protocols.
Yes. The four technologies can be used independently or in combination. The treating professional is responsible for patient assessment, sequencing, settings, and any combination protocol.
DPC™ and VermaDerm™ handpieces use built-in CoolTip™ sapphire contact cooling to protect the epidermal surface and support comfort during treatment. Comfort measures for laser and radiofrequency protocols depend on the selected handpiece and protocol.
The system brings technology selection and treatment parameters into one interface. Its software includes default parameters based on SharpLight clinical protocols while also allowing trained practitioners to use manual settings where appropriate.
The platform spans DPC™ interfaces at 1.5, 3.4, and 6.4 cm²; VermaDerm™ interfaces at 3.4 and 6.4 cm²; Fractional 2940 options at 9×9, 7×7, and 4 mm; and 3/6 mm LP and 2/4/6/12 mm QS laser spots. Availability depends on the installed handpiece configuration.
No single recovery profile applies to the whole platform. Many DPC™, radiofrequency, and infrared protocols are non-invasive, while fractional resurfacing and laser procedures can involve different preparation, recovery, and aftercare. The practitioner should explain the protocol-specific expectations before treatment.
OmniMax S4 is professional medical-aesthetic equipment. It should be operated only by appropriately trained and qualified practitioners who follow the applicable user manuals, contraindications, local regulations, safety requirements, and approved indications.
Contactez notre équipe pour réserver une démo et constater les résultats par vous-même. Investissez dans votre entreprise avec une technologie d’esthétique médicale transformative.