Rapid Series03

Rapid Series / 810 diode laser

Rapid Phantom

High-speed coverage.Precision on demand.

A diode-laser hair-removal workstation with GLIDE and EDGE handpieces, Dynamic and Flow modes, and continuous CoolTip™ sapphire contact cooling.

Designed aroundHair Reduction for All
Wavelength
810 nm diode
Handpieces
GLIDE + EDGE
Delivery
Dynamic + Flow

On the treatment floor

Watch theRapidPHANTOM

See Rapid Phantom combine pulse-by-pulse precision, in-motion treatment speed, and continuously cooled diode delivery in a clinical protocol.

  • 810 nm diode
  • GLIDE + EDGE
  • Dynamic + Flow modes
Product videoVoir la vidéo

Aperçu de la plateforme

Two handpieces, two delivery modes, one diode protocol

Rapid Phantom is a professional diode-laser platform designed for hair removal and hair reduction. Its 810 nm wavelength supports selective energy delivery to the hair follicle across protocol-appropriate skin types and treatment areas.

Dynamic Hair Removal (DHR) delivers controlled pulses at 1 Hz with 5–40 J/cm² fluence and 30–100 ms pulse widths. Flow Hair Removal (FHR) uses 2–10 J/cm² at 5–10 Hz for continuous in-motion coverage with pulse widths up to 27 ms.

GLIDE combines a 3.0 cm² spot and 1200 W output for larger zones. EDGE uses a 1.6 cm² spot and 600 W output for detailed or contoured areas. Both support Dynamic and Flow modes without changing the treatment platform.

CoolTip™ sapphire contact cooling operates at the skin surface, while a closed-loop liquid-cooling system regulates the workstation internally. A 10.2-inch colour touchscreen brings mode and treatment settings into one interface.

  • 810 nm

    Diode wavelength

  • 2

    Dedicated handpieces

  • 5–10 Hz

    Flow repetition rate

Conception de la plateforme

Designed around a dual-mode diode protocol

Six protocol details connect cooling, control, mobility, handpiece selection, and dual-mode diode delivery in one self-contained platform.

  • CoolTip™ sapphire cooling

    Continuous CoolTip™ sapphire contact cooling supports epidermal protection and patient comfort throughout energy delivery.

  • 10.2-inch colour touchscreen

    A clear interface brings treatment mode, parameters, and system status into one practitioner-led protocol.

  • Compact mobile footprint

    A 103 × 44 × 46 cm workstation and 43 kg system weight support movement between treatment spaces.

Rapid Phantom diode-laser workstation with mounted handpiece
Dual-mode diode workstation
  • GLIDE and EDGE compatibility

    Two dedicated handpieces cover broad body zones and detailed contours with 3.0 cm² and 1.6 cm² spots.

  • Dynamic and Flow delivery

    Dynamic stamping pulse-by-pulse treatment and in-motion Flow treatment options provide the flexibility to tailor every treatment for optimal speed, precision, and patient comfort.

  • Built for High-Performing Clinics

    A dedicated diode laser platform engineered to deliver consistent, efficient hair removal treatments day after day.

Meet the handpieces

Coverage when it counts.
Precision where it matters.

GLIDE and EDGE share the same diode wavelength, CoolTip™ cooling, and dual-mode delivery while matching spot size and power to the treatment area.

Large-area handpiece
3.0cm² spot

High-speed / large spot

GLIDE

Best suited for
Back · Legs · Chest · Arms
Diffusion d’énergie
1200 W · Dynamic 5–40 J/cm² · Flow 2–10 J/cm²
Operating speed
Dynamic 1 Hz · Flow 5–10 Hz
Precision handpiece
1.6cm² spot

Precision / compact spot

EDGE

Best suited for
Beard line · Upper lip · Underarms · Bikini
Diffusion d’énergie
600 W · Dynamic 5–40 J/cm² · Flow 2–10 J/cm²
Operating speed
Dynamic 1 Hz · Flow 5–10 Hz
810 nmDiode Laser
1.6 + 3.0 cm²Precision and coverage spots
1–10 HzDynamic and Flow speeds
CoolTip™Sapphire contact cooling technology

Détail de la pièce à main

HR 635

01 / 02

Profil latéral

Why choose Rapid Phantom

Precision meets speed

One diode platform. Four practical advantages across precision and large-area hair-removal protocols.

Treatment speed

Large-area efficiency

Pair GLIDE’s 3.0 cm² spot and 1200 W output with Flow mode for efficient in-motion coverage across larger treatment zones.

Treatment geometry

Contour-ready precision

Use EDGE’s 1.6 cm² spot and 600 W output for controlled treatment around detailed, smaller, or contoured areas.

Mode flexibility

Protocol flexibility

Move between higher-fluence Dynamic pulses and lower-fluence Flow delivery without changing workstations or core technology.

Patient comfort

Continuous contact cooling

CoolTip™ sapphire windows provide active surface cooling throughout treatment to support comfort and epidermal protection.

En salle de traitement

Rapid Phantom workstation in a professional treatment room
01 / 04

Full workstation with dual handpieces on a mobile base

Référence technique

Rapid Phantom technical specifications

Rapid Phantom diode-laser workstation in a purple studio setting
Rapid SeriesRapid Phantom

Core performance

Technology
Diode laser
Wavelength
810 nm
Primary indication
Hair removal and hair reduction
Dynamic fluence
5–40 J/cm²
Flow fluence
2–10 J/cm²
Dynamic pulse width
30–100 ms
Flow pulse width
Up to 27 ms
Repetition rate
Dynamic: 1 Hz · Flow: 5–10 Hz

Handpiece family

GLIDE
3.0 cm² · 1200 W
EDGE
1.6 cm² · 600 W
Shared modes
Dynamic Hair Removal (DHR) and Flow Hair Removal (FHR)
Shared cooling
CoolTip™ sapphire contact cooling

Cooling & safety

Contact cooling
CoolTip™ sapphire window with continuous active cooling
Internal cooling
Closed-loop liquid cooling with active temperature regulation

System & hardware

Display
10.2-inch high-definition colour touchscreen
Electrical
120–240 V AC, 50–60 Hz, 9–5 A
Dimensions
103 cm H × 44 cm W × 46 cm D
Total weight
43 kg / 94.8 lb

Documented outcomes

See the difference.
Control the view.

Explore documented before-and-after imagery relevant to Rapid Phantom. Drag the divider across each image to inspect the result from either side.

Individual results vary by patient, protocol, practitioner, and treatment plan.

Après — Hair Removal case 1
Avant — Hair Removal case 1
AvantAprès

Réponses aux questions cliniques

Rapid Phantom
questions fréquentes

Des renseignements pratiques pour les cliniques qui évaluent la plateforme.

L’admissibilité au traitement, les paramètres et les soins après traitement doivent être déterminés par un praticien SharpLight formé, à la suite d’une consultation et d’un test cutané.

What is the SharpLight Rapid Phantom?

Rapid Phantom is an 810 nm diode-laser platform designed for professional hair removal and hair reduction. It combines Dynamic Hair Removal (DHR) and Flow Hair Removal (FHR) modes with GLIDE and EDGE handpieces for broad and precision treatment areas.

Why is the 810 nm diode wavelength widely used for hair removal?

The 810 nm wavelength balances melanin absorption with penetration depth, helping trained practitioners direct laser energy toward the hair follicle while following protocol-specific measures intended to protect surrounding skin.

What is the difference between GLIDE and EDGE?
  • GLIDE: a 3.0 cm², 1200 W handpiece for efficient coverage of larger body areas such as the back, legs, chest, and arms.
  • EDGE: a 1.6 cm², 600 W handpiece for detailed or contoured areas such as the beard line, upper lip, underarms, and bikini area.

Both handpieces support Dynamic and Flow modes and include CoolTip™ sapphire contact cooling.

How are Dynamic and Flow modes different?
  • Dynamic Hair Removal (DHR) delivers individual higher-fluence pulses at 1 Hz for controlled, pulse-by-pulse treatment.
  • Flow Hair Removal (FHR) uses lower fluence at 5–10 Hz while the handpiece moves continuously across the treatment area.
Which Fitzpatrick skin types can Rapid Phantom treat?

Rapid Phantom is designed to support hair-removal protocols across Fitzpatrick Skin Types I–VI. Treatment suitability, mode, fluence, and cooling settings must be selected by a trained practitioner after consultation and skin assessment; recent tanning can affect treatment timing and parameters.

How does CoolTip™ support treatment comfort?

Each handpiece includes a continuously cooled CoolTip™ sapphire contact window. It cools the skin surface before and during energy delivery to support epidermal protection and patient comfort throughout the selected protocol.

How many sessions are usually included in a treatment plan?

Most patients require 6–8 treatments, spaced according to the hair growth cycle, to achieve optimal long-term hair reduction. The exact number of sessions depends on factors such as the treatment area, hair colour and thickness, skin type, and individual response to treatment. Periodic maintenance sessions may be recommended to help maintain results.

What does a Rapid Phantom treatment feel like?

Flow mode is designed to feel like a gradually warming, gliding treatment, while Dynamic mode can feel like a brief light snap with each pulse. Sensation varies by area, settings, and individual sensitivity; CoolTip™ cooling operates throughout treatment.

Is downtime expected after treatment?

Rapid Phantom hair-removal protocols are generally intended without planned downtime. Temporary redness or perifollicular erythema can occur and commonly settles within several hours. Patients should follow their practitioner’s instructions and report unexpected or persistent effects.

What post-treatment care is recommended?
  • Use broad-spectrum SPF 50+ on exposed treatment areas.
  • Avoid direct sun exposure for four weeks after treatment or as directed by the treating professional.
  • Avoid hot tubs, saunas, and intense exercise for 24–48 hours when advised.
  • Follow all area-specific instructions provided by the treating professional.
Réservez votre démo aujourd’hui!

découvrez sharplight en action

Contactez notre équipe pour réserver une démo et constater les résultats par vous-même. Investissez dans votre entreprise avec une technologie d’esthétique médicale transformative.

  • Plateformes multi-technologies et mono-technologies
  • Plus de 60 indications cliniques, 16 pièces à main
  • Essai pratique des séries OmniMax et Rapid
Demander une démo
Brochure du produit

Télécharger la brochure Rapid Phantom

Indiquez-nous comment vous joindre et la brochure s’ouvrira immédiatement.