Rapid Series04

Rapid Series / DPC™ + Long-pulse Nd:YAG

Rapid Vanish

Hair, vascular, pigment.One focused platform.

A three-handpiece platform combining DPC™ HR for hair reduction on Fitzpatrick I–V, DPC™ VP² for vascular and pigment spot treatment, and long-pulse Nd:YAG 1064 nm for vein removal on Fitzpatrick I–IV and hair reduction on Fitzpatrick V–VI.

Designed aroundHair, Vascular & Pigment
Handpieces
DPC™ HR + VP² + Nd:YAG
Skin types
Fitzpatrick I–V / V–VI
Technologies
DPC™ + Laser

On the treatment floor

Watch theRapid Vanish

See how Rapid Vanish combines DPC™ HR, DPC™ VP², and long-pulse Nd:YAG 1064 nm for hair, vascular, and pigment protocols.

  • DPC™ HR + VP²
  • 1064 nm Nd:YAG
  • Hair · vascular · pigment
Product videoVoir la vidéo

Aperçu de la plateforme

Three handpieces. Hair, vascular & pigment.

Rapid Vanish combines DPC™ HR, DPC™ VP², and long-pulse Nd:YAG 1064 nm in one focused workstation. DPC™ HR supports hair reduction on Fitzpatrick skin types I–V without FLOW Mode.

DPC™ VP² provides focused spot treatment for vascular and pigmented imperfections, including broken capillaries, sun spots, age spots, and superficial lesions.

Long-pulse Nd:YAG 1064 nm supports spider and superficial vein removal on Fitzpatrick skin types I–IV and hair reduction on Fitzpatrick skin types V–VI.

Together, the handpieces let clinics treat hair, vascular, and pigment concerns across the face and body, making those imperfections vanish.

  • 3

    Technology handpieces

  • I–V / V–VI

    Hair-reduction skin types

  • Hair · vascular · pigment

    Spot-treatment indications

Conception de la plateforme

Designed around hair, vascular & pigment

Three application-specific handpieces connect hair reduction, vascular treatment, and pigment spot treatment in one self-contained platform.

  • DPC™ HR hair reduction

    DPC™ HR delivers hair-reduction protocols for Fitzpatrick skin types I–V, with no FLOW Mode required.

  • DPC™ VP² spot treatment

    Focused DPC™ VP² delivery supports targeted treatment of vascular and pigmented imperfections.

  • Long-pulse Nd:YAG 1064 nm

    Long-pulse 1064 nm supports vein removal for Fitzpatrick skin types I–IV and hair reduction for darker skin types V–VI.

Rapid Vanish long-pulse Nd:YAG workstation with mounted handpiece
Hair, vascular, and pigment workstation
  • Three application-specific handpieces

    HR, VP², and LP Nd:YAG handpieces keep hair, vascular, and pigment protocols together on one workstation.

  • 10.2-inch colour touchscreen

    A clear interface brings treatment parameters, system status, and calibration into one practitioner-led protocol.

  • Compact mobile footprint

    A self-contained mobile workstation is designed to move between treatment spaces.

Meet the handpieces

Three handpieces.
One focused platform.

DPC™ HR, DPC™ VP², and long-pulse Nd:YAG 1064 nm handpieces cover hair reduction, vascular treatment, and pigment spot treatment.

DPC™ handpieces
HR 635DPC™

Hair reduction · Fitzpatrick I–V

DPC™ HR

Best suited for
Face and body hair reduction · No FLOW Mode
Diffusion d’énergie
DPC™ HR protocol
Operating speed
Protocol-dependent
Laser handpiece
3 / 6mm tips

Vein removal · I–IV / Hair reduction · V–VI

LP LASER 1064

Best suited for
Spider and superficial veins · I–IV / Darker-skin hair reduction · V–VI
Diffusion d’énergie
30–350 J/cm² · 4–30 ms
Operating speed
Up to 1 Hz
DPC™ HRHair reduction · I–V
DPC™ VP²Vascular + pigment spot treatment
1064 nmVein removal · I–IV / Hair reduction · V–VI
3 / 6 mmNd:YAG spot sizes

Détail de la pièce à main

HR 635

01 / 02

Profil latéral

Why choose Rapid Vanish

Make imperfections vanish.

One platform to clear your clients' skin imperfections.

Inclusive

Hair reduction across skin types

DPC™ HR supports Fitzpatrick I–V, while long-pulse Nd:YAG 1064 nm extends hair-reduction protocols to V–VI.

Targeted Treatments

Vascular and pigment spot treatment

DPC™ VP² targets localized vascular and pigmented imperfections such as broken capillaries, sun spots, and age spots.

Laser Technology

Long-pulse Nd:YAG reach

The 1064 nm wavelength supports vein removal and deeper hair-reduction protocols on darker skin types.

Clinical protocol

Focused, flexible workstation

Switch between three application-specific handpieces while keeping parameter selection and system monitoring in one place.

En salle de traitement

Rapid Vanish workstation in a treatment room
01 / 02

Full workstation — mobile base with dual handpiece cradles

Référence technique

Rapid Vanish technical specifications

Rapid Vanish touchscreen, LP LASER 1064 handpiece, and workstation detail
Rapid SeriesRapid Vanish

Core technology & delivery

Platform technologies
DPC™ HR · DPC™ VP² · Long-pulse Nd:YAG
DPC™ HR
Hair reduction · Fitzpatrick I–V · no FLOW Mode
DPC™ VP²
Vascular and pigment spot treatment
Nd:YAG laser
1064 nm · vein removal on I–IV · hair reduction on V–VI
Fluence
30–350 J/cm²
Pulse width
4–30 ms
Repetition rate
Up to 1 Hz

Cooling & control

Contact cooling
Treatment-interface contact cooling
Internal cooling
Closed-cycle system with temperature control
Display
10.2-inch colour touchscreen

Treatment interface

Handpieces
DPC™ HR · DPC™ VP² · LP LASER 1064
Nd:YAG spot diameters
3 mm · 6 mm
Indications
Hair reduction · vascular · pigment

System & hardware

Electrical
120–240 V~, 50–60 Hz, 12 A max
Dimensions
102.7 cm H × 44 cm W × 46 cm D
Total weight
53 kg

Documented outcomes

See the difference.
Control the view.

Explore documented before-and-after imagery relevant to Rapid Vanish. Drag the divider across each image to inspect the result from either side.

Individual results vary by patient, protocol, practitioner, and treatment plan.

Après — Vein Removal
Avant — Vein Removal
AvantAprès

Réponses aux questions cliniques

Rapid Vanish
questions fréquentes

Des renseignements pratiques pour les cliniques qui évaluent la plateforme.

L’admissibilité au traitement, les paramètres et les soins après traitement doivent être déterminés par un praticien SharpLight formé, à la suite d’une consultation et d’un test cutané.

What is the SharpLight Rapid Vanish?

Rapid Vanish is a professional three-handpiece platform combining DPC™ HR, DPC™ VP², and long-pulse Nd:YAG 1064 nm technologies. Together, they support hair reduction plus targeted vascular and pigment treatments across the face and body.

Which handpieces are available on Rapid Vanish?

Rapid Vanish offers three application-specific handpieces: DPC™ HR for hair reduction on Fitzpatrick skin types I–V, DPC™ VP² for targeted vascular and pigmented concerns, and LP LASER 1064 for vein removal on Fitzpatrick I–IV and hair reduction on Fitzpatrick V–VI.

What does the DPC™ HR handpiece treat?

The DPC™ HR handpiece provides hair-reduction treatments for Fitzpatrick skin types I–V. It uses SharpLight’s Dynamic Pulse Control technology and does not include DPC™ Flow Mode.

What does the DPC™ VP² handpiece treat?

The DPC™ VP² handpiece provides focused spot treatment for localized vascular and pigmented imperfections, including broken capillaries, sun spots, age spots, and other superficial concerns assessed as appropriate by the practitioner.

What does the LP LASER 1064 handpiece treat?

The long-pulse Nd:YAG 1064 nm handpiece supports spider and superficial vein removal on Fitzpatrick skin types I–IV and hair reduction on Fitzpatrick skin types V–VI. A trained practitioner determines whether a patient and concern are suitable for treatment.

What is the difference between the 3 mm and 6 mm spot sizes?

Both spot sizes are used with the LP LASER 1064 handpiece. The 3 mm spot supports more focused treatment, while the 6 mm spot provides broader coverage. The practitioner selects the appropriate spot size and parameters for the treatment area and concern.

How are treatment parameters selected?

Rapid Vanish is intended for trained medical and aesthetic professionals. The practitioner evaluates the patient’s skin type, treatment area, and concern before selecting the appropriate handpiece, spot size, and treatment parameters.

How does Rapid Vanish support treatment comfort?

The platform combines contact cooling at the treatment interface with a closed-cycle internal cooling system and temperature control. Cooling settings and treatment technique are selected by the practitioner for the chosen handpiece and protocol.

How many sessions are needed?

Treatment plans vary according to the selected handpiece, concern, treatment area, skin type, and individual response. The practitioner will recommend the number and spacing of sessions after an assessment and adjust the plan as treatment progresses.

Is downtime or aftercare expected?

The expected response depends on the handpiece and treatment performed. Temporary redness, swelling, vessel darkening, or other localized effects may occur. Patients should follow their practitioner’s indication-specific aftercare instructions, protect treated skin from sun exposure, and report unexpected or persistent effects.

Réservez votre démo aujourd’hui!

découvrez sharplight en action

Contactez notre équipe pour réserver une démo et constater les résultats par vous-même. Investissez dans votre entreprise avec une technologie d’esthétique médicale transformative.

  • Plateformes multi-technologies et mono-technologies
  • Plus de 60 indications cliniques, 16 pièces à main
  • Essai pratique des séries OmniMax et Rapid
Demander une démo
Brochure du produit

Télécharger la brochure Rapid Vanish

Indiquez-nous comment vous joindre et la brochure s’ouvrira immédiatement.